Key Lesson Learned

My chosen paint colour had an LRV of 30, which is too dark for weatherboard (timber) cladding. Many manufacturers and systems require a minimum LRV of 45 (some specify ≥40%).

What is LRV?

Light Reflectance Value (LRV) measures the percentage of visible light a painted surface reflects (scale: 0 = pure black/absorbs all light → 100 = pure white/reflects all light).

  • Lower LRV = darker colour → absorbs more solar heat
  • Higher LRV = lighter colour → reflects more heat

Why the Minimum LRV Requirement Exists

Dark colours on timber weatherboards absorb excessive heat → core timber temperature rises → problems include:

  • Excessive timber movement / expansion & contraction
  • Increased risk of resin bleed (especially in radiata pine / finger-jointed timber)
  • Faster paint degradation, cracking, or peeling
  • Potential voiding of product warranty / guarantee

Many pre-primed or treated timber weatherboard suppliers (e.g. common NZ/AU systems like EnviroPine, JSC, Niagara/Envira, OTC, etc.) explicitly state in their technical guidelines:

Use only paints with LRV ≥ 45% (and often gloss ≥10% for durability)

Some fibre-cement or insulated systems allow down to 40% or even 25% with special "CoolColour" technology, but standard timber weatherboards are stricter (usually 45%).

NZ Building Code Context

The NZBC itself does not mandate a specific LRV for timber cladding (it's not a direct code clause).
The minimum LRV requirements come from manufacturer specifications and product appraisals / warranties / CodeMark certifications.

Practical Takeaways for Future Projects

  • Always check the specific cladding manufacturer's technical data sheet for LRV limits before selecting colour.
  • LRV < 45 almost always disqualifies very dark / near-black shades on standard timber weatherboards.
  • For darker looks, consider:
    • Specialised timber products designed for low-LRV colours (e.g. thermally modified timber)
    • "CoolColour" / infrared-reflective paint technology (still check if accepted by cladding supplier)
    • Non-timber cladding options (some allow LRV 25–40%)
  • Paint suppliers (e.g. Resene) publish LRV values for each colour — verify before purchase.

Personal note: My LRV 30 colour was rejected — next selection must be ≥45 LRV to stay within warranty and performance guidelines.